ML
    • Recent
    • Categories
    • Tags
    • Popular
    • Users
    • Groups
    • Register
    • Login

    Daisy Chain Ubiquiti AC Pros?

    IT Discussion
    ubnt wifi access point ubiquiti wireless ap networking
    8
    75
    7.1k
    Loading More Posts
    • Oldest to Newest
    • Newest to Oldest
    • Most Votes
    Reply
    • Reply as topic
    Log in to reply
    This topic has been deleted. Only users with topic management privileges can see it.
    • DustinB3403D
      DustinB3403
      last edited by

      Here's some more detail on this.

      https://help.ubnt.com/hc/en-us/articles/204959454-UniFi-How-do-secondary-Ethernet-ports-work-on-UAPs-

      You'll need a PoE injector for every AP.

      PoE, AP > Bridge >Ethernet run > PoE, AP > Bridge >Ethernet run > PoE, AP > Bridge >Ethernet run > PoE, AP

      Etc

      1 Reply Last reply Reply Quote 0
      • JaredBuschJ
        JaredBusch
        last edited by

        The correct solution here is likely a PtMP solution like this

        https://help.ubnt.com/hc/en-us/articles/205197750-airMAX-Which-product-should-I-use-#3

        UniFi is not designed for this purpose. Could you shoehorn it? Sure. But it is not the design.

        DustinB3403D 1 Reply Last reply Reply Quote 1
        • DustinB3403D
          DustinB3403 @JaredBusch
          last edited by

          @JaredBusch said in daisy chain Ubiquiti AC Pros?:

          The correct solution here is likely a PtMP solution like this

          https://help.ubnt.com/hc/en-us/articles/205197750-airMAX-Which-product-should-I-use-#3

          UniFi is not designed for this purpose. Could you shoehorn it? Sure. But it is not the design.

          So you're thinking have a central unit that services each of the cottages, rather than an AP per cottage.

          Mike DavisM 1 Reply Last reply Reply Quote 0
          • Mike DavisM
            Mike Davis @DustinB3403
            last edited by

            @DustinB3403 said in daisy chain Ubiquiti AC Pros?:

            @JaredBusch said in daisy chain Ubiquiti AC Pros?:

            The correct solution here is likely a PtMP solution like this

            https://help.ubnt.com/hc/en-us/articles/205197750-airMAX-Which-product-should-I-use-#3

            UniFi is not designed for this purpose. Could you shoehorn it? Sure. But it is not the design.

            So you're thinking have a central unit that services each of the cottages, rather than an AP per cottage.

            If I understand @JaredBusch correctly, he is thinking more like a WISP solution where you put a multi point antenna on a mast and then at each cottage have a rocket mounted outside to link with the multi point and then a AC on the inside of the cottage. That was a thought too, but there are trees all over and that adds a lot of gear, which drives up the cost.

            scottalanmillerS 1 Reply Last reply Reply Quote 0
            • travisdh1T
              travisdh1 @Mike Davis
              last edited by

              @Mike-Davis said in daisy chain Ubiquiti AC Pros?:

              I'm looking at doing a wireless project for a group of cottages. Due to the layout, running a homerun cable to each AP isn't practical. To keep the costs down, I was thinking about doing this in each cottage:
              Ubiquiti ETH-SP-G2 Surge Suppressor/Protector
              PoE injector
              UAP-AC-PRO
              Ubiquiti ETH-SP-G2 Surge Suppressor/Protector

              and on to the next cottage.

              This will save on the expense of a switch in each cottage. It will also save on the expense of running home runs. Does anyone see a problem with this? The longest chain would be 3 in a row.

              I'm a little confused by this. Are you planning to run a network wire through the cottages and not doing a single run for each cottage? Seems silly compared to doing Point to Multipoint wireless like @JaredBusch already gave you a link to.

              TLDNR: All the wires or no wires, no in between there is.

              DustinB3403D 1 Reply Last reply Reply Quote 0
              • DustinB3403D
                DustinB3403 @travisdh1
                last edited by

                @travisdh1 said in daisy chain Ubiquiti AC Pros?:

                @Mike-Davis said in daisy chain Ubiquiti AC Pros?:

                I'm looking at doing a wireless project for a group of cottages. Due to the layout, running a homerun cable to each AP isn't practical. To keep the costs down, I was thinking about doing this in each cottage:
                Ubiquiti ETH-SP-G2 Surge Suppressor/Protector
                PoE injector
                UAP-AC-PRO
                Ubiquiti ETH-SP-G2 Surge Suppressor/Protector

                and on to the next cottage.

                This will save on the expense of a switch in each cottage. It will also save on the expense of running home runs. Does anyone see a problem with this? The longest chain would be 3 in a row.

                I'm a little confused by this. Are you planning to run a network wire through the cottages and not doing a single run for each cottage? Seems silly compared to doing Point to Multipoint wireless like @JaredBusch already gave you a link to.

                TLDNR: All the wires or no wires, no in between there is.

                Well, there are wires to the mast or high point where the equipment would be centrally located. But due to the tree coverage he'd be limited to the "900MHz, Better tolerance for trees and small obstacles"

                Which may not even be allowed in the area.

                Mike DavisM 1 Reply Last reply Reply Quote 1
                • Mike DavisM
                  Mike Davis
                  last edited by

                  Here is an image. The drawing is wildy not to scale. From the Main House to Birch is about 600', thus the multi mode fiber. From Lakeshore 1,2,3 to Lakeview is 115'.0_1541434307574_WirelessPlan.png

                  dafyreD 1 Reply Last reply Reply Quote 1
                  • Mike DavisM
                    Mike Davis @DustinB3403
                    last edited by

                    @DustinB3403 said in daisy chain Ubiquiti AC Pros?:

                    Well, there are wires to the mast or high point where the equipment would be centrally located. But due to the tree coverage he'd be limited to the "900MHz, Better tolerance for trees and small obstacles"
                    Which may not even be allowed in the area.

                    Due to the trees we would probably be talking 80' towers before taking the fresnel zone in to consideration.

                    DustinB3403D 1 Reply Last reply Reply Quote 0
                    • DustinB3403D
                      DustinB3403 @Mike Davis
                      last edited by

                      @Mike-Davis at AP6 are you planning to have a switch there? You said there would only be 3 AP's for the longest chain, but that's 5.

                      Mike DavisM 1 Reply Last reply Reply Quote 0
                      • DustinB3403D
                        DustinB3403
                        last edited by

                        AP 12 is just floating out there on the lake, which would mean at least a second 3 link chain.

                        Mike DavisM 1 Reply Last reply Reply Quote 0
                        • Mike DavisM
                          Mike Davis @DustinB3403
                          last edited by

                          @DustinB3403 said in daisy chain Ubiquiti AC Pros?:

                          @Mike-Davis at AP6 are you planning to have a switch there? You said there would only be 3 AP's for the longest chain, but that's 5.

                          Yes, switch at AP 6, so 7 and 8 would daisy chain to 9. I would probably be possible to run straight from the Main House to 7 and then go from 7 back to 6 and 5.

                          1 Reply Last reply Reply Quote 0
                          • Mike DavisM
                            Mike Davis @DustinB3403
                            last edited by

                            @DustinB3403 said in daisy chain Ubiquiti AC Pros?:

                            AP 12 is just floating out there on the lake, which would mean at least a second 3 link chain.

                            12 is just the legend. Sorry, should have labeled that. Used GreenShot for my napkin sketch.

                            1 Reply Last reply Reply Quote 0
                            • scottalanmillerS
                              scottalanmiller @Mike Davis
                              last edited by

                              @Mike-Davis said in daisy chain Ubiquiti AC Pros?:

                              @DustinB3403 said in daisy chain Ubiquiti AC Pros?:

                              @JaredBusch said in daisy chain Ubiquiti AC Pros?:

                              The correct solution here is likely a PtMP solution like this

                              https://help.ubnt.com/hc/en-us/articles/205197750-airMAX-Which-product-should-I-use-#3

                              UniFi is not designed for this purpose. Could you shoehorn it? Sure. But it is not the design.

                              So you're thinking have a central unit that services each of the cottages, rather than an AP per cottage.

                              If I understand @JaredBusch correctly, he is thinking more like a WISP solution where you put a multi point antenna on a mast and then at each cottage have a rocket mounted outside to link with the multi point and then a AC on the inside of the cottage. That was a thought too, but there are trees all over and that adds a lot of gear, which drives up the cost.

                              Yes, that sounds like a better solution if you can do it.

                              1 Reply Last reply Reply Quote 1
                              • coliverC
                                coliver
                                last edited by coliver

                                Seems like it wouldn't be difficult to setup a secure location outside of cabin Maple, or cabin Spruce and then home run everything there... you're pretty much already running the conduit. Then run a fiber (or Cat6e if the distance isn't that large) back to the main office. Otherwise treating this as a WISP and each cabin as a subscriber would be the best solution.

                                1 Reply Last reply Reply Quote 1
                                • dafyreD
                                  dafyre
                                  last edited by

                                  @Mike-Davis -- What makes the home run not practical?

                                  DustinB3403D Mike DavisM 2 Replies Last reply Reply Quote 0
                                  • DustinB3403D
                                    DustinB3403
                                    last edited by DustinB3403

                                    I still only count 11 AP's @Mike-Davis. Your legend is stating 12. Where would the last one be?

                                    coliverC 1 Reply Last reply Reply Quote 0
                                    • coliverC
                                      coliver @DustinB3403
                                      last edited by

                                      @DustinB3403 said in daisy chain Ubiquiti AC Pros?:

                                      I still only count 11 AP's then @Mike-Davis. Your legend is stating 12. Where would the last one be?

                                      I think 12 is just a reference to denote the symbol for the APs. It's not the actual number.

                                      DustinB3403D 1 Reply Last reply Reply Quote 0
                                      • DustinB3403D
                                        DustinB3403 @dafyre
                                        last edited by

                                        @dafyre said in daisy chain Ubiquiti AC Pros?:

                                        @Mike-Davis -- What makes the home run not practical?

                                        Conduit, digging, man power etc.

                                        1 Reply Last reply Reply Quote 0
                                        • Mike DavisM
                                          Mike Davis @dafyre
                                          last edited by

                                          @dafyre The distances and cost. Pretty sure I'd be pushing the limit if I ran from 1 to 3 or 4 directly. Also that would mean probably going to 1" conduit so I could get 3 runs of tough wire in it. All said, that would be less expensive than erecting towers to a WISP style solution, so when you compare it to that, the cost doesn't seem so bad.

                                          1 Reply Last reply Reply Quote 0
                                          • dafyreD
                                            dafyre @Mike Davis
                                            last edited by dafyre

                                            @Mike-Davis said in daisy chain Ubiquiti AC Pros?:

                                            Here is an image. The drawing is wildy not to scale. From the Main House to Birch is about 600', thus the multi mode fiber. From Lakeshore 1,2,3 to Lakeview is 115'.0_1541434307574_WirelessPlan.png

                                            Question: Do you already have a switch in Lakeview 1,2 & 3?

                                            Looking at the map, what I would suggest is a switch and Cat 6 (or fiber) to Hemlock (#5).

                                            Then Cat 6 from 6,7,8, and 9 back to Hemlock (#5). Then, Cat 6 from the Lakeview Up & Down (#3) and Balsam (#4) back to Hemlock (#5).

                                            A simple home run from the Office (#1) to Lakeshore (#2) should be fine there.

                                            Edit: I don't see any practical way to do this without having to run some cable.

                                            DustinB3403D 1 Reply Last reply Reply Quote 1
                                            • 1
                                            • 2
                                            • 3
                                            • 4
                                            • 1 / 4
                                            • First post
                                              Last post